Home    Renewable Energy    Solar lnverter    Solar Pump Inverter PV300 22KW
22KW

Solar Pump Inverter PV300 22KW

PV300 Solar pump system, consisting of solar array, solar pump inverter, AC water pump and water tank, uses solar cell as power supply to directly take water from deep wells, rivers, lakes and other water sources through the water pump. The solar array absorbs solar radiation and converts it into electric energy to provide power supply for the whole system.
Online Inquiry

PV300 Series Solar Pump Inverter

Solar pumping inverter is used to control and regulate the operation of solar water pump system (PV pumping system). It can convert the DC from the solar array into AC to drive the water pump.
Half of the energy produced around the world is used to operate pumps. Compared to diesel generator pumps, our solar pumping inverter are environmentally friendly, with a long lifetime and low maintenance costs. It is independent from the grid and produces no pollution or noise. Typical applications are irrigation, community water supply, fish farming and agriculture.

 

Product Features
◇ The solar pumping inverter is suitable for all kinds of pumps, including single phase 220V pump.
◇ With water level detection function, automatically regulate the pump flow to prevent dry running, full water level, etc.
◇ The solar pumping inverter is easy installation and effortless maintenance.
◇ Standard RS485 interface, support to remote monitor the system with the software on PC.


Power Range
1-Phase 220VAC pump: 0.4~5.5kW
3-Phase 220VAC pump: 0.4~11kW
3-Phase 380VAC pump: 0.75~110kW

 

Technical Specification

Model Motor Rated output current (A) Suggested open circuit voltage (V)
kW HP
Single phase output 220V
PV300-0R4G-S2 0.4 0.5 4 350~400
PV300-0R7G-S2 0.75 1 7 350~400
PV300-1R5G-S2 1.5 2 9.6 350~400
PV300-2R2G-S2 2.2 3 17 350~400
PV300-004G-S2 4.0 5 25 350~400
PV300-5R5G-S2 5.5 7.5 32 350~400
Three phase output 220V
PV300-0R4G-S2 0.4 0.5 2.3 350~400
PV300-0R7G-T2 0.75 1 4 350~400
PV300-1R5G-T2 1.5 2 7 350~400
PV300-2R2G-T2 2.2 3 9.6 350~400
PV300-004G-T2 4.0 5 17 350~400
PV300-5R5G-T2 5.5 7.5 25 350~400
PV300-7R5G-T2 7.5 10 32 350~400
PV300-011G-T2 11 15 45 350~400
Three phase output 380V
PV300-0R7G-T4 0.75 1 2.1 625~750
PV300-1R5G-T4 1.5 2 3.8 625~750
PV300-2R2G-T4 2.2 3 6 625~750
PV300-004G-T4 4.0 5 9 625~750
PV300-5R5G-T4 5.5 7.5 13 625~750
PV300-7R5G-T4 7.5 10 17 625~750
PV300-011G-T4 11 15 25 625~750
PV300-015G-T4 15 20 32 625~750
PV300-018G-T4 18.5 25 37 625~750
PV300-022G-T4 22 30 45 625~750
PV300-030G-T4 30 40 60 625~750
PV300-037G-T4 37 50 75 625~750
PV300-045G-T4 45 60 90 625~750
PV300-055G-T4 55 75 110 625~750
PV300-075G-T4 75 100 150 625~750
PV300-090G-T4 90 125 176 625~750
PV300-110G-T4 110 150 210 625~750

 

Item Technical Index Specification
Input Input DC voltage 150~440V (220V pump)     300~900V (380V pump)
Output Output voltage 0~rated input voltage
Control  Features Control mode V/f control
Sensorless vector control
Operation command mode Keypad control  Terminal control
Serial communication control
Frequency setting mode MPPT automatic regulation CVT (constant voltage)
Overload capacity 150% 60s, 180% 10s, 200% 3s.
Starting torque 0.5Hz/ 150% (SVC); 1Hz/ 150% (V/f)
Speed adjustment range 1:100 (SVC), 1:50 (V/f)
Speed control ±0.5% (SVC)
  precision  
Carrier frequency 1.0~ 16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracy Digital setting: 0.01Hz
Analog setting: maximum frequency * 0.05%
Torque boost Automatically torque boost;     
manually torque boost: 0.1%~30.0%
V/f curve Three types: linear, multiple point and square type ( 1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/ deceleration mode Straight line / S curve; four kinds of acceleration/deceleration time,
range: 0.1s~3600.0s
Control  Function Over-voltage & over-current stall control Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection function Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure &
has fault automatic reset function
Special functions for solar pump system MPPT (Maximum Power Point Tracking), dry tap protection,    water level sensor failure protection, full water warning, weak  sunshine warning, full automatic running, automatic switching of PV input and other power inputs.
Input/ output terminals Input terminals Programmable DI: 3 on-off inputs 1 programmable AI: 0~10V or 0/4~20mA
Output terminals 2 relay outputs
Communication terminals Offer RS485 communication interface, support MODBUS-RTU communication protocol
Human  machine interface LED display Display frequency setting, output frequency, output voltage, output current, etc.
Multifunction key QUICK/JOG key, can be used as multifunction key
Environ- ment Ambient temperature -10℃~40℃ , derated 4% when the temperature rise by every 1 ℃ (40℃~50℃).
Humidity 90%RH or less (non-condensing)
Altitude ≤1000M: output rated power, >1000M: output derated
Storage temperature -20℃~60℃

 

E-mail:sales@spdrive.com