Photovoltaic Pump Controller PV300 5.5KW-11KW
PV300 Series Solar Pump Inverter
Solar pumping inverter is used to control and regulate the operation of solar water pump system (PV pumping system). It can convert the DC from the solar array into AC to drive the water pump.
Half of the energy produced around the world is used to operate pumps. Compared to diesel generator pumps, our solar pumping inverter are environmentally friendly, with a long lifetime and low maintenance costs. It is independent from the grid and produces no pollution or noise. Typical applications are irrigation, community water supply, fish farming and agriculture.
Product Features
◇ The solar pumping inverter is suitable for all kinds of pumps, including single phase 220V pump.
◇ With water level detection function, automatically regulate the pump flow to prevent dry running, full water level, etc.
◇ The solar pumping inverter is easy installation and effortless maintenance.
◇ Standard RS485 interface, support to remote monitor the system with the software on PC.
Power Range
1-Phase 220VAC pump: 0.4~5.5kW
3-Phase 220VAC pump: 0.4~11kW
3-Phase 380VAC pump: 0.75~110kW
Technical Specification
Model | Motor | Rated output current (A) | Suggested open circuit voltage (V) | |
kW | HP | |||
Single phase output 220V | ||||
PV300-0R4G-S2 | 0.4 | 0.5 | 4 | 350~400 |
PV300-0R7G-S2 | 0.75 | 1 | 7 | 350~400 |
PV300-1R5G-S2 | 1.5 | 2 | 9.6 | 350~400 |
PV300-2R2G-S2 | 2.2 | 3 | 17 | 350~400 |
PV300-004G-S2 | 4.0 | 5 | 25 | 350~400 |
PV300-5R5G-S2 | 5.5 | 7.5 | 32 | 350~400 |
Three phase output 220V | ||||
PV300-0R4G-S2 | 0.4 | 0.5 | 2.3 | 350~400 |
PV300-0R7G-T2 | 0.75 | 1 | 4 | 350~400 |
PV300-1R5G-T2 | 1.5 | 2 | 7 | 350~400 |
PV300-2R2G-T2 | 2.2 | 3 | 9.6 | 350~400 |
PV300-004G-T2 | 4.0 | 5 | 17 | 350~400 |
PV300-5R5G-T2 | 5.5 | 7.5 | 25 | 350~400 |
PV300-7R5G-T2 | 7.5 | 10 | 32 | 350~400 |
PV300-011G-T2 | 11 | 15 | 45 | 350~400 |
Three phase output 380V | ||||
PV300-0R7G-T4 | 0.75 | 1 | 2.1 | 625~750 |
PV300-1R5G-T4 | 1.5 | 2 | 3.8 | 625~750 |
PV300-2R2G-T4 | 2.2 | 3 | 6 | 625~750 |
PV300-004G-T4 | 4.0 | 5 | 9 | 625~750 |
PV300-5R5G-T4 | 5.5 | 7.5 | 13 | 625~750 |
PV300-7R5G-T4 | 7.5 | 10 | 17 | 625~750 |
PV300-011G-T4 | 11 | 15 | 25 | 625~750 |
PV300-015G-T4 | 15 | 20 | 32 | 625~750 |
PV300-018G-T4 | 18.5 | 25 | 37 | 625~750 |
PV300-022G-T4 | 22 | 30 | 45 | 625~750 |
PV300-030G-T4 | 30 | 40 | 60 | 625~750 |
PV300-037G-T4 | 37 | 50 | 75 | 625~750 |
PV300-045G-T4 | 45 | 60 | 90 | 625~750 |
PV300-055G-T4 | 55 | 75 | 110 | 625~750 |
PV300-075G-T4 | 75 | 100 | 150 | 625~750 |
PV300-090G-T4 | 90 | 125 | 176 | 625~750 |
PV300-110G-T4 | 110 | 150 | 210 | 625~750 |
Item | Technical Index | Specification |
Input | Input DC voltage | 150~440V (220V pump) 300~900V (380V pump) |
Output | Output voltage | 0~rated input voltage |
Control Features | Control mode | V/f control Sensorless vector control |
Operation command mode | Keypad control Terminal control Serial communication control |
|
Frequency setting mode | MPPT automatic regulation CVT (constant voltage) | |
Overload capacity | 150% 60s, 180% 10s, 200% 3s. | |
Starting torque | 0.5Hz/ 150% (SVC); 1Hz/ 150% (V/f) | |
Speed adjustment range | 1:100 (SVC), 1:50 (V/f) | |
Speed control | ±0.5% (SVC) | |
precision | ||
Carrier frequency | 1.0~ 16.0kHz, automatically adjusted according to temperature and load characteristics | |
Frequency accuracy | Digital setting: 0.01Hz Analog setting: maximum frequency * 0.05% |
|
Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% |
|
V/f curve | Three types: linear, multiple point and square type ( 1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
Acceleration/ deceleration mode | Straight line / S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s |
|
Control Function | Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping |
Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function |
|
Special functions for solar pump system | MPPT (Maximum Power Point Tracking), dry tap protection, water level sensor failure protection, full water warning, weak sunshine warning, full automatic running, automatic switching of PV input and other power inputs. | |
Input/ output terminals | Input terminals | Programmable DI: 3 on-off inputs 1 programmable AI: 0~10V or 0/4~20mA |
Output terminals | 2 relay outputs | |
Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
Multifunction key | QUICK/JOG key, can be used as multifunction key | |
Environ- ment | Ambient temperature | -10℃~40℃ , derated 4% when the temperature rise by every 1 ℃ (40℃~50℃). |
Humidity | 90%RH or less (non-condensing) | |
Altitude | ≤1000M: output rated power, >1000M: output derated | |
Storage temperature | -20℃~60℃ |