SW300 Industrial&Commercial Pump Controller
Main Features:
1.IP65 rated enclosure for dust-tight and water-resistant protection.
2.Dual RS485 communication (SG+/SG- & A/B), dual output relays (1A/2A & 1C/2C);
3.Single-phase 220V models feature built-in EMC input filter and PFC power factor correction;
4.Dual alarm fault display: simultaneously displays fault code and corresponding fault indicator light;
5.Protection rating IP55: waterproof, dustproof, rustproof, and corrosion-resistant;
6.Intelligent constant pressure control, compatible with various types of sensors, with customizable sensorless constant pressure control;
7.Multi-pump parallel operation: supporting up to six pumps in parallel.
Power Range:
Single phase 220V 0.75kW-4.0kW
Three phases 380V 0.75kW-15kW
Specifications and Dimensions:
| Model | Rated Power (kW) | Output Current (A) | Applicable Motor (kW) | Dimensions (mm) | |||||
| H | H1 | H2 | W | W2 | D | ||||
| SW300-2S0.7 | 0.75 | 4 | 0.75 | 212 | 155 | 155 | 257 | 90 | 110 |
| SW300-2S1.5 | 1.5 | 6.6 | 1.5 | ||||||
| SW300-2S2.2 | 2.2 | 9.6 | 2.2 | ||||||
| SW300-4T0.7 | 0.75 | 2.2 | 0.75 | ||||||
| SW300-4T1.5 | 1.5 | 3.8 | 1.5 | ||||||
| SW300-4T2.2 | 2.2 | 5.1 | 2.2 | ||||||
| SW300-4T3.0 | 3 | 6.2 | 3 | ||||||
| SW300-4T4.0 | 4 | 9 | 4 | ||||||
| SW300-4T5.5 | 5.5 | 13 | 5.5 | ||||||
| SW300-4T7.5 | 7.5 | 17 | 7.5 | ||||||
| SW300-4T11 | 11 | 25 | 11 | 276 | 180 | 196 | 312 | 95 | 140 |
| SW300-4T15 | 15 | 32 | 15 | ||||||
| SW300-4T18 | 18.5 | 37 | 18.5 | ||||||
| SW300-4T22 | 22 | 45 | 22 | ||||||
| SW300-4T30 | 30 | 60 | 30 | ||||||
| VoltageClass | 220V | 380V |
| Product Model | SW300-2SXXX | SW300-4TXXX |
| Output Frequency Range (Hz) | 0~500Hz | |
| Speed Adjustment Range | Wide speed range, control accuracy: VF 1:50, SVC 1:100 | |
| Rated Input Voltage (V) | Single-phase 220V | Three-phase 380V |
| Input Frequency and Voltage Tolerance | Frequency: 50/60Hz, Voltage tolerance: ±15% | |
| Control Method | Vector V/F control (VVF) | |
| Sensorless vector control (SVC) | ||
| Torque Characteristics | Low-frequency load capacity: VF 1Hz/150%, SVC 0.5Hz/150% | |
| Overload Capacity | 150% for 1 minute, 120% for 50 minutes | |
| Acceleration/Deceleration Time | 0.1~3000 seconds (independently settable) | |
| V/F Curve | Provides straight line and arbitrary V/F control curves. | |
| Frequency Setting Signal - Keypad Operation | Set by ▲▼ keys | |
| Frequency Setting Signal - External Signal | Potentiometer 5kΩ/0.5W, DC 0~+10V (input impedance 47kΩ), 4~20mA (output impedance 250Ω), multi-function input selection 1~2 (2-speed, jog, up/down commands, etc.), communication setting | |
| Operation Characteristics - Keypad Operation | Set by RUN/STOP keys | |
| Operation Characteristics - External Signal | X1-X3 combination for various operation modes; RS-485 communication port | |
| Multi-function Input Signals | Multi-speed command 0-2 selection, jog command, external EF (NC) selection | |
| Multi-function Output Signals | Up to 9 types of multi-function outputs | |
| Other Functions | AVR function, overvoltage stall prevention, DC braking, fault record, DC braking start frequency setting, parameter lock/reset, carrier frequency adjustment | |
| Protection Functions | Overvoltage, overcurrent, undervoltage, overload limit, overtemperature, self-test, self-diagnosis, industry-specific detection protection | |
| Cooling Method | Self-cooling for 11kW and below; forced air cooling for 11kW above | |
| Installation Site | Altitude below 1000m | |
| Ambient Temperature | -20℃~40℃ | |
| Storage Temperature | -30℃~80℃ | |
| Vibration | Below 20Hz: 9.8066 m/s² (1G), 20~60Hz: 5.88 m/s² (0.6G) | |
| Protection Level | IP55 | |