SF760 Series High-Performance Vector Frequency Inverter
Power Range:
Three Phase AC 340V-460V 0.75kW-560kW
Three Phase AC 520V-690V 18.5kW-450kW
Product Features:
◇ Equipment of a built-in DC reactor (in case of an inverter of above 18.5kW) can reduce input current distortion, increase the power factor and promote the product reliability;
◇ High torque control accuracy: SVC/±5% rated torque, FVC/±3% rated torque;
◇ Wide speed range and high control accuracy: SVC/1:200 (±0.2%), FVC/1:1000 (±0.02%) rated speed;
◇ Low-frequency carrier: VVF/3Hz/150%, SVC/0.25Hz/150%, FVC/0Hz/180%;
◇ Protections against overvoltage stall, fast current limit, overload, overheat, off-load, overspeed, and so on;
◇ Support I/O expansion: 3-channel digital inputs, 2-channel relay outputs, 1-channel -10V~ 10V voltage input, 1-channel sensor input;
◇ Support communication bus expansion: standard configuration including 485 bus, optional PROFINET, CANopen and EtherCAT;
◇ Support various encoders: ABZ incremental, UVW incremental, UVW wire saver, rotary transformer and sine-cosine transformer;
◇ Support debugging by the mobile phone APP or monitoring of the inverter status;
◇ Support Wi-Fi module or serial port access;
◇ Rich and convenient PC background software functions.
Rated voltage of power supply | Model | Applicable motor power (kW) | Rated output current (A) |
Three-phase AC 340~460V |
SF760-0R7G/1R5P-3B | 0.75/1.5 | 2.5/4.2 |
SF760-1R5G/2R2P-3B | 1.5/2.2 | 4.2/5.6 | |
SF760-2R2G/3R0P-3B | 2.2/3.0 | 5.6/7.2 | |
SF760-4R0G/5R5P-3B | 4.0/5.5 | 9.4/12 | |
SF760-5R5G/7R5P-3B | 5.5/7.5 | 13/17 | |
SF760-7R5G/9R0P-3B | 7.5/9.0 | 17/20 | |
SF760-011G/015P-3B | 11/15 | 25/32 | |
SF760-015G/018P-3B | 15/18.5 | 32/38 | |
SF760-018G/022P-3B | 18.5/22 | 38/44 | |
SF760-022G/030P-3B | 22/30 | 45/59 | |
SF760-030G/037P-3/3B | 30/37 | 60/73 | |
SF760-037G/045P-3/3B | 37/45 | 75/87 | |
SF760-045G/055P-3/3B | 45/55 | 90/106 | |
SF760-055G/075P-3/3B | 55/75 | 110/145 | |
SF760-075G/090P-3/3B | 75/90 | 150/169 | |
SF760-090G/110P-3 | 90/110 | 176/208 | |
SF760-110G/132P-3 | 110/132 | 210/248 | |
SF760-132G/160P-3 | 132/160 | 253/298 | |
SF760-160G/185P-3 | 160/185 | 304/350 | |
SF760-200G/220P-3 | 200/220 | 380/410 | |
SF760-220G/250P-3 | 220/250 | 426/456 | |
SF760-250G/280P-3 | 250/280 | 465/510 | |
SF760-280G/315P-3 | 280/315 | 520/573 | |
SF760-315G/355P-3 | 315/355 | 585/640 | |
SF760-355G/400P-3 | 355/400 | 650/715 | |
SF760-400G/450P-3 | 400/450 | 725/810 | |
SF760C-450G/500P-3 | 450/500 | 820/900 | |
SF760C-500G/560P-3 | 500/560 | 900/1010 | |
SF760C-560G/630P-3 | 560/630 | 1010/1140 | |
Three-phase AC 520~690V |
SF760-018G/022P-6B | 18.5/22 | 25/28 |
SF760-022G/030P-6B | 22/30 | 28/35 | |
SF760-030G/037P-6B | 30/37 | 35/42 | |
SF760-037G/045P-6B | 37/45 | 42/52 | |
SF760-045G/055P-6B | 45/55 | 52/63 | |
SF760-055G/075P-6B | 55/75 | 63/86 | |
SF760-075G/090P-6B | 75/90 | 86/95 | |
SF760-090G/110P-6 | 90/110 | 95/120 | |
SF760-110G/132P-6 | 110/132 | 120/147 | |
SF760-132G/160P-6 | 132/160 | 147/175 | |
SF760-160G/185P-6 | 160/185 | 175/200 | |
SF760-185G/200P-6 | 185/200 | 200/221 | |
SF760-200G/220P-6 | 200/220 | 221/235 | |
SF760-220G/250P-6 | 220/250 | 235/270 | |
SF760-250G/280P-6 | 250/280 | 270/300 | |
SF760-280G/315P-6 | 280/315 | 300/330 | |
SF760-315G/355P-6 | 315/355 | 330/380 | |
SF760-355G/400P-6 | 355/400 | 380/426 | |
SF760-400G/450P-6 | 400/450 | 426/465 | |
SF760-450G/500P-6 | 450/500 | 465/540 |
Item | Specification | |
Power supply | Rated voltage of power supply | Three-phase 340V-10%~460V+10% (three-phase 380V) Three-phase 520V-15%~690V+10% (three-phase 660V) 50-60Hz ± 5%; voltage unbalance rate: <3% |
Output | Maximum output voltage | The maximum output voltage is the same as the input power voltage. |
Rated output current | Continuous output of 100% rated current | |
Maximum overload current | G model: 150% rated current for 60s P model: 120% rated current for 60s (2kHz carrier; please derate for carriers above this level) |
|
Basic control functions | Driving mode | V/F control (VVF) Speed sensorless vector control (SVC); Speed sensor vector control (FVC) |
Input mode | Frequency (speed) input, torque input | |
Start and stop control mode | Keyboard, control terminal (two-line control and three-line control), communication | |
Frequency control range | 0.00~600.00Hz/0.0~3000.0Hz | |
Input frequency resolution | Digital input: 0.01Hz Analog input: 0.1% of maximum frequency | |
Speed control range | 1:50 (VVF), 1:200 (SVC), 1:1000 (FVC) | |
Speed control accuracy | ±0.5% (VVF), ±0.2% (SVC), ±0.02% (FVC) | |
Acceleration and deceleration time | 0.01 s to 600.00 s / 0.1 s to 6,000.0 s / 1 s to 60,000 s | |
Voltage/frequency characteristics | Rated output voltage: 20% to 100%, adjustable; fundamental frequency: 1Hz to 600Hz/3000Hz, adjustable | |
Torque boost | Fixed torque boost curve, any V/F curve optional | |
Starting torque | 150%/3Hz (VVF), 150%/0.25Hz (SVC), 180%/0Hz (FVC) | |
Torque control accuracy | ±5% rated torque (SVC), ±3% rated torque (FVC) | |
Self-adjustment of output voltage | When the input voltage changes, the output voltage will basically remain unchanged. | |
Automatic current limit | Output current is automatically limited to avoid frequent overcurrent trips. | |
DC braking | Braking frequency: 0.01 to maximum frequency Braking time: 0~30S Braking current: 0% to 150% rated current |
|
Signal input source | Communication, multi-speed, analog, high-speed pulse, etc. | |
Input and output function | Reference power supply | 10.5V±0.5V/20mA |
Terminal control power | 24V/200mA | |
Digital input terminal | 7 (standard X1 to X7) + 3 (extension card X8 to X10) digital multi-function inputs: X7 can be used as a high-speed pulse input terminal (F02.06 = 35/38/40); The remaining 9 channels (X1 to X6 and X8 to X10) can only be used as ordinary digital input terminals. |
|
Analog input terminal | 3 (standard AI1 to AI3) + 1 (extension card AI4) analog inputs: One AI1: support 0 to 10V or -10 to 10V, optional through function code F02.62; Two AI2/AI3: support 0 to 10V or 0 to 20mA or 4 to 20mA, optional through function codes F02.63 and F02.64; One AI4: support 0 to 10V or -10 to 10V, optional through function code F02.65 |
|
Digital output terminal | 2 (standard Y1/Y2) open-collector multi-function outputs + 2 (R1: EA/EB/EC and R2: RA/RB/RC) relay multi-function outputs + 2 (extension card) (R3: RA3/RC3 and R4: RA4/RC4) relay multi-function outputs, max. current 50 mA for collector output; Relay contact capacity 250VAC/3A or 30VDC/1A, with EA-EC and RA-RC normally open, EB-EC and RB-RC normally closed; RA3-RC3, RA4-RC4 normally open |
|
Analog output terminal | Two (M1/M2) multi-function analog output terminals, with output of 0 to 10V or 0 to 20mA or 4 to 20mA, optional for selection by using function codes F03.34 and F03.35 |
|
Operation panel | LCD display | The standard LCD displays relevant information about the inverter. |
Parameter copying | Parameter settings of the inverter can be uploaded and downloaded for fast parameter copying. | |
Protection | Protective Function | Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheat, overspeed, load loss, external fault, etc. |
Use conditions | Location | Indoor, at an altitude of less than 1 km, free of dust, corrosive gases and direct sunlight |
Applicable environment | -10℃ to +50℃, derating by 5% per 1℃ increase above 40℃, 20% to 90%RH (non-condensing) | |
Vibration | Less than 0.5g | |
Storage environment | -40℃~+70℃ | |
Installation method | Wall-mounted, floor-standing electrical control cabinet, through-wall | |
Protection level | Standard IP21/IP20 (remove the plastic cover at the top of the plastic case) | |
Cooling method | Forced air cooling |